SHERIFF ZX-999ER
Posted Jul 9th, 2007 10:34AMSTANDARD FUNCTIONS OF SYSTEM
The basic difference from the previous version the range of work of a pager increased to 2000 metres.
Dynamic code KeeLoq.
The two-channel receiver (possibility of programming to 4 transmitters).
Two two-push-button programmed transmitters.
Push-button switch Valet.
The two-level gauge of blow.
Siren.
The built in relay of management of dimensional fires.
The built in universal power exit of management of locks of doors.
Management of the central lock of the car in mode Valet and at the working engine.
Two demountable connections for connection of external gauges of blow and volume.
Two chains blocking (installation of the additional relay is required).
Not programmed channel CH2 of management activated from the transmitter service devices of the car (the luggage carrier electric drive, system of remote start etc.).
Additional programmed control path service devices (the channel of additional blocking, an exit of polite illumination etc.).
The multipurpose light-emitting diode indicator.
Memory of operations.
Manual statement of system on protection at any time by means of button Valet in a mode of full protection. Silent statement and removal of system from protection.
Temporary switching-off of the gauge of blow.
Temporary switching-off of function of Passive Statement on protection.
Switching-off of an alarm signal from a remote control.
Remote control by function the Panic in all modes.
Sound acknowledgement of mode Valet.
Sound and light acknowledgement of operating modes of system.
The sound and light prevention of system operation.
Detour of a zone of malfunction.
Limited time of a mode of alarm.
Input of the negative trigger of protection of a cowl, luggage carrier.
Inputs of triggers of positive and negative polarity of trailer switches of doors.
Automatic repeated statement of system on protection in 20 seconds
Memory of conditions DISARM, VALET, Triggers after removal of pressure of a food.
PROGRAMMED FUNCTIONS OF SYSTEM
Programmed function of an immobilizer (passive blocking of the engine).
Programmed personal code of switching-off and management of system.
Programmed delay of statement of system on protection: 5 seconds, 35 seconds
Passive/active statement of system on protection.
Programmed auto lock-out of locks of doors at passive statement on protection.
Programmed automatic lock-out of doors at ignition inclusion.
Programmed automatic unlocking of doors at ignition deenergizing.
Programmed function of restatement on protection.
Control mode programming by the central lock at restatement on protection.
Programmed duration of an impulse of management of locks of doors: 1 seconds, 3,5 seconds
Double impulse of unlocking of doors.
To close all (an impulse of closing by duration 28 seconds).
Programmed function of management by the additional channel 3 (Management of the additional normally opened relay of blocking or an exit (-) during 30 sec at system statement on protection or an exit (-) during 30 sec at removal of system from protection. Multichannel Anti-Hi-Jack: remote inclusion, inclusion at operation of trailer switches of doors and ignition inclusion.
Programmed delay of inclusion of a siren at system operation.
Long-term deenergizing of signals of confirmation of a siren.
Programmed function of switching-off of “false” operations of system